POWER QUALITY SOLUTIONS

VarSet LV

image-1

Fully type tested in compliance with IEC/EN 61439-1 & 2, IEC 61921; Network voltage: 230V-400V-415V-690V (50Hz), 240V-400V-480V-600V (60Hz); Wall mounted enclosures from 9kvar to 300kvar - Floor standing cubicles from 50kvar to 1150kvar; Automatic compensation for variable-unstable loads up to 1150kvar - Fixed compensation for stable loads up to 200kvar; Modbus communication (Varlogic NRC12 and communication module in option) for integration with building management systems; Detuned reactor tuning: 2.7 (135Hz), 3.8 (190Hz), 4.2 (210Hz); Thermal control devices;

ReactiVar Standard Automatic Power Factor Capacitor Banks

image-1

Square D ReactiVar Standard Automatic Power Factor Capacitor Banks are ideally suited for centralized power factor correction in applications where plant loading is constantly changing.;

ReactiVar Automatic Anti-Resonant Power Factor Capacitor Banks

image-1

In today's industrial electrical networks, high harmonic content would damage standard fixed or automatic capacitor banks. The ReactiVar® AV6000 Anti-Resonant Power Factor capacitor bank is specifically designed to provide power factor correction. Iron core reactors are added in series with capacitor modules. The reactors tune the bank below the first dominant harmonic (usually the 5th). Below the tuning point, the system appears capacitive and thus corrects power factor in the system. Above the turning point, the system appears inductive and thus the resonance is minimized. It also has the added advantage to remove up to 50% of the 5th harmonic current in the system. ;

ReactiVar Passive Harmonic Filter Systems

image-1

Square D ReactiVar AV7000 filtered capacitor bank is designed to provide harmonic filtering in industrial networks where harmonic energies are causing nuisance tripping of circuit breakers, faulty PLC operation and overheating of transformers and cables.

ReactiVar Hybrid VAR Compensator

image-1

ReactiVar® Hybrid VAR Compensator (HVC) provides real time power factor correction, voltage support, and harmonic suppression in electrical distribution networks with highly cyclical load profiles. Benefits include increased system capacity, improved product quality, increased system reliability and proven energy savings. The HVC system mixes fixed banks of standard, tuned or de-tuned capacitor banks and AccuSine® PFV electronic VAR compensation unit to provide rapid response and "stageless" kVAR control never before seen in a power factor correction product. It can be applied either in low voltage or medium voltage electrical distribution networks.;

ReactiVar Medium Voltage Metal Enclosed Automatic Power Factor Capacitor Banks

image-1

Large industrial power users (over 5 MW) can benefit from centralized power factor compensation and harmonic mitigation at the medium voltage level. The ReactiVar® medium voltage automatic power factor correction banks are ideally suited for centralized power factor correction in applications where plant load fluctuates resulting in the need for varying amounts of reactive power. Depending on the level of the harmonic content in the network, you can select standard (MV5000), anti-resonant (MV6000), or filtered (MV7000) capacitor systems. An advanced microprocessor-based reactive power controller measures plant power factor via a single remote current transformer (not included), and switches capacitor modules in and out of service to maintain user-selected target power factor. ;

AccuSine Power Correction System

image-1

Power electronic devices which have repaid and frequent load variations have become abundant today due to their many process control related and energy saving benefits. However, they also bring couple major drawbacks in electrical distribution system; harmonics and rapid change of reactive power requirement. Harmonics may disrupt normal operation of other devices and increase operating costs. Rapid reactive power requirement change demands timely var compensation;

ReactiVar Transient Free Reactive Compensation Systems

image-1

Square D ReactiVar Transient Free Reactive Compensation Systems represents an enhancement in conventional power factor correction and harmonic filtering technology;

Go Pel Company was founded back in 2002 in Italy. We started our business with selling good quality products, like electrical generators, plugs, transformers, connectors, switches, etc. Our mission is to offer our Clients the highest level regarding specialization, organization, flexibility and product quality acquired over decades of experience, together with all the latest innovations resulting from our continuous research.