600V NF Panelboards

image-1

Eleven standard boxes and common trims with NF panelboards. Available with six circuit counts – 18, 30, 42, 54, 72 and 84. A change in the 2008 National Electric Code will eliminate the 42 circuit rule and allow a higher number of circuits in a single enclosure. A full compliment of field installable accessories available for RTI panelboards. Feed-through and sub-feed lugs; Sub-feed circuit breakers; 200% neutrals; Copper neutrals and grounds; 6”, 12” and 18” rail and deadfront extension kits; “Semi-assembled” RTI kits with more visually oriented, easier to understand installation instructions.

240V NQ Lighting Panelboards

image-1

240Vac, 48Vdc maximum; 600 Amp maximum main circuit breakers or main lugs; 150 Amp maximum branch circuit breakers; 10K thru 200K SCCR; Fully rated or series rated systems are available; Vertically mounted main and sub-feed circuit breakers; Ready-to-install main circuit breaker kits convert main lug interiors; Interiors are field convertible to top or bottom feed; Interiors available in plated copper or aluminum bus; An interior accepts bolt-on or plug-on branch circuit breakers; Complete line of UL Listed interiors with 200% rated neutrals for non-linear loads;

Square D NQ 300 A Loadcentres

image-1

Presenting the Square D NQ 300A loadcentres exclusively designed to meet the large amperage needs of residential homes. They are ideal for homes that use applications such as electric vehicle charging stations, electrical furnaces etc. and need a compact solution at the same time. These loadcentres come fully assembled and are available in multiple configurations to meet the different needs of contractors and homeowners.

NQ Lighting Panelboards

image-1

3P4W and 1P3W available; 100A, 225A, 400A and 600A Interiors available; 10kA, 22kA and 65kA fully rated branches at 208Y/120Vac; Series ratings to 200kA and 208Y/120Vac; Available with six circuit counts – 18, 30, 42, 54, 72 and 84. A full compliment of field installable accessories available for RTI panelboards. Feed-through and sub-feed lugs; Sub-feed circuit breakers; 200% neutrals; Copper neutrals and grounds; NQ accepts both QO® “plug-on” and QOB “bolt-on” circuit breakers. Type 1,3R, 4, 4X, 5, and 12 enclosures; Compatible with H-, J- and L-Frame PowerPact with Micrologic circuit breakers for faster recognition of faults at main level for critical applications.

NF Lighting Panelboards

image-1

3P4W and 1P3W available; 125A, 250A, 400A, 600A and 800A Interiors available; Fully Rated branches: o 480Y/277Vac: 18kA, 35kA, and 65kA; o 600Y/347Vac: 14kA, 18kA, and 35kA; Series ratings; o 200kA at 480Y/277Vac; o 200kA at 600Y/347Vac; Available with six circuit counts: 18, 30, 42, 54, 66 and 84. A full compliment of field installable accessories available for RTI panelboards. Feed-through and sub-feed lugs; Sub-feed circuit breakers; 200% neutrals; Copper neutrals and grounds; Type 1,3R, 4, 4X, 5, and 12 enclosures; Compatible with H-, J- and L-Frame PowerPact with Micrologic circuit breakers for faster recognition of faults at main level for critical applications.

I-Line Power Distribution Panelboards

image-1

600Vac, 250Vdc maximum; 1200 Amp main circuit breaker or main lugs; 1200 Amp maximum branch circuit breaker; UL Listed for use on systems with up to 200K max. RMS symmetrical amperes available fault current when using current limiting main or branch circuit breakers; Fully rated and series rated systems available; Branch circuit breaker mounting flexibility; capable of mounting a 15A circuit breaker next to or across from a 1200A circuit breaker; Circuit breakers on right-hand side of I-Line® bus stack completely independent of position and frame size of circuit breakers on left-hand side; Circuit breaker plug-on jaws have no fasteners – less time spent on installation and maintenance; Circuit breakers do not require any additional external mounting hardware; Average branch circuit breaker installation time less than one minute; Circuit breaker connections are “blow-on” type which draw the connector jaws together, providing a firmer grip under high level short circuit conditions; Circuit breakers include a push-to-trip feature to exercise the tripping mechanism; Well suited to rearranging circuits;

I-Line Smart Cell

image-1

The modular Square D™ I-Line™ Smart Cell enables value-added devices in I-Line panelboards in a variety of combinations. The space-saving unit fits into the I-Line bus in place of a breaker, and allows the I-Line panelboard to be transformed into a digital communication or metered electrical distribution solution.

I-Line Combo Panelboard

image-1

600y/347 Vac, 48 Vdc maximum; 1200 A maximum main circuit breaker or 800 A maximum main lug; 1200 A maximum branch circuit breaker; 200,000 A SCCR when using current limiting main or branch circuit breakers; Fully rated and series rated systems available; Interiors available in plated copper or aluminum bus; Complete line of cULus listed interiors with 200% rated neutrals for non-linear loads; Sub-feed or through-feed lugs through 1200 A; Interiors accept plug-on thermal magnetic or electronic trip branch circuit breakers;

QMB Fusible Power Distribution Panelboards

image-1

For use on ac or dc systems; Underwriters Laboratories ® (UL ®) Listed under File E6294 and File E33139, and CSA File Location LL-1809-75; Suitable for use as service equipment; Insulated, solid neutral may be bonded to the box with a grounding strap;

Integrated Power Center (IPC2)

image-1

Integrated Power Center 2 (IPC2™) lineups can be applied throughout your facility wherever multiple panelboards, transformers and/or lighting contactors are located in close proximity.

Modular Panelboard System

image-1

Consists of a mix of NQ, NF, NF Column-Width, NF PowerLink Gen 3, Single Row I-Line, Double Row I-Line and QMB panelboards. Equipment Space, Lighting Contactors, and TVSS also available. Significantly reduce the space traditionally required for electrical distribution equipment up to 40%. The factories assembled and wired systems lower installed cost up to 20%. Pre-assembled construction reduces the total installation time at the job site. Distribution equipment can be configured from a broad product offering to provide customer-specific solutions and permit shorter lead times.

Go Pel Company was founded back in 2002 in Italy. We started our business with selling good quality products, like electrical generators, plugs, transformers, connectors, switches, etc. Our mission is to offer our Clients the highest level regarding specialization, organization, flexibility and product quality acquired over decades of experience, together with all the latest innovations resulting from our continuous research.